Steel Worker Quarter Electrical Wiring Installation Note

- Sep 29, 2020-

1. All wires in the house should be laid out and covered with non-combustible pipe troughs. Double-slope color steel movable houses. The wires should not be installed in the ceiling. It is necessary to prevent the phenomenon of random pulling of wires.

2. The lamps and lanterns should keep a safe distance from the board wall. Fluorescent lamps should use electronic ballasts instead of coil inductive ballasts.

3. The wire passes through the wall panel of the color steel clip, and must be covered with porcelain pipe or other non-combustible plastic tube. Because the wall panel is holed, the polystyrene in the color steel plate, the wire passes through the wall without a casing It must be in contact with it.When the wire catches fire due to excessive short circuit, load, and excessive contact resistance, sparks; it will inevitably ignite polystyrene and cause a fire.

4. Each unit and each board room of the color steel plate movable house must be installed with qualified, quality leakage protection switches and short-circuit and overload protection switches. When short-circuit, leakage or overload occurs, the power supply can be cut off in time to avoid wires. Fire with electrical appliances and then ignite the board room.

5. It is forbidden to use electric cups, rice cookers, electric stoves, and other electric heating appliances in the board room. Avoid short circuit and overload of wires caused by excessive power consumption.

6. The color steel plate movable room must be equipped with lightning protection devices, and the steel structure must have grounding protection.

7. It is forbidden to use sharp board house metal as electric welding ground wire.

8. It is forbidden to use electric welding or gas welding to cut and weld the splint of the color steel plate movable room.

Steel Worker Quarter Electrical Wiring Installation Note